{"id":117701,"date":"2022-11-01T08:00:36","date_gmt":"2022-11-01T08:00:36","guid":{"rendered":"https:\/\/www.pbctoday.co.uk\/news\/?p=117701"},"modified":"2022-11-10T11:16:00","modified_gmt":"2022-11-10T11:16:00","slug":"fire-performance-requirements-cavity-trays-masonry-facades","status":"publish","type":"post","link":"https:\/\/www.pbctoday.co.uk\/news\/building-control-news\/fire-performance-requirements-cavity-trays-masonry-facades\/117701\/","title":{"rendered":"Understanding the changing fire performance requirements of cavity trays in masonry facades"},"content":{"rendered":"<h2>The way we construct masonry buildings has developed, with many projects moving away from traditional non-combustible blockwork inner leaves in favour of cost-effective, quicker-to-erect steel framing systems (SFS). This has meant reconsidering the fire performance of elements installed within the cavity, including the cavity tray<\/h2>\n<p>While cavity trays do not fulfil a <a href=\"https:\/\/www.pbctoday.co.uk\/news\/stakeholders\/siderise-insulation-limited-fire-protection-solutions\/103294\/\" target=\"_blank\" rel=\"noopener noreferrer\">passive fire protection<\/a> function, Approved Document B England: Volume 1 and 2 (ADB) Regulation 7 states that for high-rise residential and other relevant buildings over 18m, they (alongside other key facade elements) must achieve an A1 or A2-s1,d0 Euroclass rating under EN13501- 1, unless they are installed between two leaves of masonry.<\/p>\n<p>On 1 June 2022, the government announced further amendments to ADB. This introduced a range of measures, from expanding the definition of higher-risk buildings to banning certain materials. At the same time, it also announced an 18-month temporary relaxation, ending in December 2023, which exempts cavity trays from the non-combustible fire performance requirement in all construction methods.<\/p>\n<h3>Industry found securing non-combustible approaches \u2018challenging\u2019<\/h3>\n<p>This has been done in response to the 2020 consultation &#8211; Review of the Ban on the Use of Combustible Materials in and on the External Walls of Buildings. The responses suggested that the industry had been finding it challenging to find suitable approaches to ensure non-combustibility. Many had been resorting to bending sheet metal and packing it out with non-combustible insulation onsite.<\/p>\n<p>The relaxation is intended to give the industry time to catch up in terms of innovating new<br \/>\ncavity tray solutions that will comply with the regulations. However, in the two years since the consultation, solutions have been developed that already tick all the boxes.<\/p>\n<h3>Futureproof solutions to fire performance<\/h3>\n<p>New cavity tray solutions are now available that combine flexible aluminium cavity trays with integral, pre-compressed non-combustible insulation. This creates a single-component product that provides reliable quality with several practical benefits.<\/p>\n<p>As a single product, they can be holistically tested to ensure an accurate fire reaction classification. There are also products available that are backed by warranties from major providers such as <a href=\"https:\/\/www.pbctoday.co.uk\/news\/stakeholders\/nhbc-warranty-insurance\/81202\/\" target=\"_blank\" rel=\"noopener noreferrer\">NHBC<\/a>, <a href=\"https:\/\/www.pbctoday.co.uk\/news\/?p=21008\" target=\"_blank\" rel=\"noopener noreferrer\">Premier Guarantee<\/a> and <a href=\"https:\/\/www.pbctoday.co.uk\/news\/stakeholders\/labc-providing-expert-independent-public-service-building-control-through-local-authorities\/91690\/\" target=\"_blank\" rel=\"noopener noreferrer\">LABC<\/a>.<\/p>\n<p>Practically, they are also obviously much quicker and easier to install than forming the solution onsite &#8211; requiring just a cutting knife and sealing tape for joining at details such as corners or windows &#8211; with no need to add additional insulation or use sealants.<\/p>\n<h3>Meeting the right requirements now<\/h3>\n<p>While we still have 12 months to go until the exemption is lifted, the government has already stated that it intends to \u201censure that non-combustible cavity trays are used in the external walls of buildings where they are readily available\u201d.<a href=\"https:\/\/www.pbctoday.co.uk\/news\/featured\/the-digital-role-in-passive-fire-protection\/113709\/\" target=\"_blank\" rel=\"noopener noreferrer\"> Solutions that not only meet this fire performance requirement but are backed by relevant warranties<\/a> and assurances can help to achieve full compliance with the regulations from the outset, ensuring a safe and effective building built for the future.<\/p>\n<p>&nbsp;<\/p>\n<div class=\"page\" title=\"Page 1\">\n<div class=\"section\">\n<div class=\"layoutArea\">\n<div class=\"column\">\n<p><strong>Helen Massay<\/strong><\/p>\n<p>Marketing Manager<\/p>\n<p>Siderise Insulation Ltd<\/p>\n<p>Tel: +44 (0) 1656 730833<\/p>\n<p><a href=\"mailto:enquiries@siderise.com\" target=\"_blank\" rel=\"noopener noreferrer\">enquiries@siderise.com<\/a><\/p>\n<p><a href=\"http:\/\/www.siderise.com\" target=\"_blank\" rel=\"noopener noreferrer\">www.siderise.com<\/a><\/p>\n<p><a href=\"https:\/\/twitter.com\/Siderise\" target=\"_blank\" rel=\"noopener noreferrer\">Twitter<\/a><\/p>\n<\/div>\n<\/div>\n<\/div>\n<\/div>\n<p><em>*Please note: This is a commercial profile<\/em><\/p>\n<div class=\"mk-custom-module-container\">\n<\/div>","protected":false},"excerpt":{"rendered":"<p>The way we construct masonry buildings has developed, with many projects moving away from traditional non-combustible blockwork inner leaves in favour of cost-effective, quicker-to-erect steel framing systems (SFS). This has meant reconsidering the fire performance of elements installed within the cavity, including the cavity tray<\/p>\n","protected":false},"author":17,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_monsterinsights_skip_tracking":false,"_monsterinsights_sitenote_active":false,"_monsterinsights_sitenote_note":"","_monsterinsights_sitenote_category":0,"footnotes":""},"categories":[306],"tags":[568,464,172727,110,586,155271,106071],"stakeholder_rel_tag":[172520],"contributor_rel_tag":[],"class_list":{"0":"post-117701","1":"post","2":"type-post","3":"status-publish","4":"format-standard","6":"category-building-control-news","7":"tag-building-regulations","8":"tag-contributor-profile","9":"tag-featured","10":"tag-fire-safety-management","11":"tag-insulation","12":"tag-pbc-today-november-2022","13":"tag-sh-siderise-insulation-limited","14":"stakeholder_rel_tag-siderise-insulation"},"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v26.9 (Yoast SEO v26.9) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>Understanding the changing fire performance requirements of cavity trays in masonry facades<\/title>\n<meta name=\"description\" content=\"Construction of masonry buildings has moved towards steel framing systems, meaning the fire performance has to be reconsidered\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.pbctoday.co.uk\/news\/building-control-news\/fire-performance-requirements-cavity-trays-masonry-facades\/117701\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Understanding the changing fire performance requirements of cavity trays in masonry facades\" \/>\n<meta property=\"og:description\" content=\"Construction of masonry buildings has moved towards steel framing systems, meaning the fire performance has to be reconsidered\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.pbctoday.co.uk\/news\/building-control-news\/fire-performance-requirements-cavity-trays-masonry-facades\/117701\/\" \/>\n<meta property=\"og:site_name\" content=\"Planning, Building &amp; Construction Today\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/PBCToday\/\" \/>\n<meta property=\"article:published_time\" content=\"2022-11-01T08:00:36+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2022-11-10T11:16:00+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.pbctoday.co.uk\/news\/wp-content\/uploads\/2022\/10\/IMAGE-1-1.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"778\" \/>\n\t<meta property=\"og:image:height\" content=\"550\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"Steph Carpenter\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:creator\" content=\"@PBC_Today\" \/>\n<meta name=\"twitter:site\" content=\"@PBC_Today\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\/\/www.pbctoday.co.uk\/news\/building-control-news\/fire-performance-requirements-cavity-trays-masonry-facades\/117701\/#article\",\"isPartOf\":{\"@id\":\"https:\/\/www.pbctoday.co.uk\/news\/building-control-news\/fire-performance-requirements-cavity-trays-masonry-facades\/117701\/\"},\"author\":{\"name\":\"Steph Carpenter\",\"@id\":\"https:\/\/www.pbctoday.co.uk\/news\/#\/schema\/person\/dd16f5e0e89ad310c0ff814f9325eb65\"},\"headline\":\"Understanding the changing fire performance requirements of cavity trays in masonry facades\",\"datePublished\":\"2022-11-01T08:00:36+00:00\",\"dateModified\":\"2022-11-10T11:16:00+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\/\/www.pbctoday.co.uk\/news\/building-control-news\/fire-performance-requirements-cavity-trays-masonry-facades\/117701\/\"},\"wordCount\":504,\"commentCount\":0,\"publisher\":{\"@id\":\"https:\/\/www.pbctoday.co.uk\/news\/#organization\"},\"keywords\":[\"Building Regulations\",\"Contributor Profile\",\"Featured\",\"Fire Safety Management\",\"Insulation\",\"PBC Today November 2022\",\"SH Siderise Insulation Limited\"],\"articleSection\":[\"Building Control News\"],\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\/\/www.pbctoday.co.uk\/news\/building-control-news\/fire-performance-requirements-cavity-trays-masonry-facades\/117701\/#respond\"]}],\"copyrightYear\":\"2022\",\"copyrightHolder\":{\"@id\":\"https:\/\/www.pbctoday.co.uk\/news\/#organization\"}},{\"@type\":\"WebPage\",\"@id\":\"https:\/\/www.pbctoday.co.uk\/news\/building-control-news\/fire-performance-requirements-cavity-trays-masonry-facades\/117701\/\",\"url\":\"https:\/\/www.pbctoday.co.uk\/news\/building-control-news\/fire-performance-requirements-cavity-trays-masonry-facades\/117701\/\",\"name\":\"Understanding the changing fire performance requirements of cavity trays in masonry facades\",\"isPartOf\":{\"@id\":\"https:\/\/www.pbctoday.co.uk\/news\/#website\"},\"datePublished\":\"2022-11-01T08:00:36+00:00\",\"dateModified\":\"2022-11-10T11:16:00+00:00\",\"description\":\"Construction of masonry buildings has moved towards steel framing systems, meaning the fire performance has to be reconsidered\",\"breadcrumb\":{\"@id\":\"https:\/\/www.pbctoday.co.uk\/news\/building-control-news\/fire-performance-requirements-cavity-trays-masonry-facades\/117701\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/www.pbctoday.co.uk\/news\/building-control-news\/fire-performance-requirements-cavity-trays-masonry-facades\/117701\/\"]}]},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/www.pbctoday.co.uk\/news\/building-control-news\/fire-performance-requirements-cavity-trays-masonry-facades\/117701\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/www.pbctoday.co.uk\/news\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Understanding the changing fire performance requirements of cavity trays in masonry facades\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/www.pbctoday.co.uk\/news\/#website\",\"url\":\"https:\/\/www.pbctoday.co.uk\/news\/\",\"name\":\"Planning, Building &amp; Construction Today\",\"description\":\"The Latest Planning, Building &amp; Construction News\",\"publisher\":{\"@id\":\"https:\/\/www.pbctoday.co.uk\/news\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/www.pbctoday.co.uk\/news\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https:\/\/www.pbctoday.co.uk\/news\/#organization\",\"name\":\"Planning, Building & Construction Today\",\"alternateName\":\"PBC Today\",\"url\":\"https:\/\/www.pbctoday.co.uk\/news\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/www.pbctoday.co.uk\/news\/#\/schema\/logo\/image\/\",\"url\":\"https:\/\/www.pbctoday.co.uk\/news\/wp-content\/uploads\/2022\/01\/pbctoday-logo-yoast-seo-organisation-1920-1080-001.jpg\",\"contentUrl\":\"https:\/\/www.pbctoday.co.uk\/news\/wp-content\/uploads\/2022\/01\/pbctoday-logo-yoast-seo-organisation-1920-1080-001.jpg\",\"width\":1920,\"height\":1080,\"caption\":\"Planning, Building & Construction Today\"},\"image\":{\"@id\":\"https:\/\/www.pbctoday.co.uk\/news\/#\/schema\/logo\/image\/\"},\"sameAs\":[\"https:\/\/www.facebook.com\/PBCToday\/\",\"https:\/\/x.com\/PBC_Today\"]},{\"@type\":\"Person\",\"@id\":\"https:\/\/www.pbctoday.co.uk\/news\/#\/schema\/person\/dd16f5e0e89ad310c0ff814f9325eb65\",\"name\":\"Steph Carpenter\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/www.pbctoday.co.uk\/news\/#\/schema\/person\/image\/\",\"url\":\"https:\/\/secure.gravatar.com\/avatar\/97a073c56b415b32c4d1d8ee9ef9a0ce42224c6532ccc712f228b71f15b4e650?s=96&d=mm&r=g\",\"contentUrl\":\"https:\/\/secure.gravatar.com\/avatar\/97a073c56b415b32c4d1d8ee9ef9a0ce42224c6532ccc712f228b71f15b4e650?s=96&d=mm&r=g\",\"caption\":\"Steph Carpenter\"},\"sameAs\":[\"http:\/\/www.pbctoday.co.uk\"],\"url\":\"https:\/\/www.pbctoday.co.uk\/news\/author\/stephhazlegreaves\/\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"Understanding the changing fire performance requirements of cavity trays in masonry facades","description":"Construction of masonry buildings has moved towards steel framing systems, meaning the fire performance has to be reconsidered","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.pbctoday.co.uk\/news\/building-control-news\/fire-performance-requirements-cavity-trays-masonry-facades\/117701\/","og_locale":"en_US","og_type":"article","og_title":"Understanding the changing fire performance requirements of cavity trays in masonry facades","og_description":"Construction of masonry buildings has moved towards steel framing systems, meaning the fire performance has to be reconsidered","og_url":"https:\/\/www.pbctoday.co.uk\/news\/building-control-news\/fire-performance-requirements-cavity-trays-masonry-facades\/117701\/","og_site_name":"Planning, Building &amp; Construction Today","article_publisher":"https:\/\/www.facebook.com\/PBCToday\/","article_published_time":"2022-11-01T08:00:36+00:00","article_modified_time":"2022-11-10T11:16:00+00:00","og_image":[{"width":778,"height":550,"url":"https:\/\/www.pbctoday.co.uk\/news\/wp-content\/uploads\/2022\/10\/IMAGE-1-1.jpg","type":"image\/jpeg"}],"author":"Steph Carpenter","twitter_card":"summary_large_image","twitter_creator":"@PBC_Today","twitter_site":"@PBC_Today","schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.pbctoday.co.uk\/news\/building-control-news\/fire-performance-requirements-cavity-trays-masonry-facades\/117701\/#article","isPartOf":{"@id":"https:\/\/www.pbctoday.co.uk\/news\/building-control-news\/fire-performance-requirements-cavity-trays-masonry-facades\/117701\/"},"author":{"name":"Steph Carpenter","@id":"https:\/\/www.pbctoday.co.uk\/news\/#\/schema\/person\/dd16f5e0e89ad310c0ff814f9325eb65"},"headline":"Understanding the changing fire performance requirements of cavity trays in masonry facades","datePublished":"2022-11-01T08:00:36+00:00","dateModified":"2022-11-10T11:16:00+00:00","mainEntityOfPage":{"@id":"https:\/\/www.pbctoday.co.uk\/news\/building-control-news\/fire-performance-requirements-cavity-trays-masonry-facades\/117701\/"},"wordCount":504,"commentCount":0,"publisher":{"@id":"https:\/\/www.pbctoday.co.uk\/news\/#organization"},"keywords":["Building Regulations","Contributor Profile","Featured","Fire Safety Management","Insulation","PBC Today November 2022","SH Siderise Insulation Limited"],"articleSection":["Building Control News"],"inLanguage":"en-US","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/www.pbctoday.co.uk\/news\/building-control-news\/fire-performance-requirements-cavity-trays-masonry-facades\/117701\/#respond"]}],"copyrightYear":"2022","copyrightHolder":{"@id":"https:\/\/www.pbctoday.co.uk\/news\/#organization"}},{"@type":"WebPage","@id":"https:\/\/www.pbctoday.co.uk\/news\/building-control-news\/fire-performance-requirements-cavity-trays-masonry-facades\/117701\/","url":"https:\/\/www.pbctoday.co.uk\/news\/building-control-news\/fire-performance-requirements-cavity-trays-masonry-facades\/117701\/","name":"Understanding the changing fire performance requirements of cavity trays in masonry facades","isPartOf":{"@id":"https:\/\/www.pbctoday.co.uk\/news\/#website"},"datePublished":"2022-11-01T08:00:36+00:00","dateModified":"2022-11-10T11:16:00+00:00","description":"Construction of masonry buildings has moved towards steel framing systems, meaning the fire performance has to be reconsidered","breadcrumb":{"@id":"https:\/\/www.pbctoday.co.uk\/news\/building-control-news\/fire-performance-requirements-cavity-trays-masonry-facades\/117701\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.pbctoday.co.uk\/news\/building-control-news\/fire-performance-requirements-cavity-trays-masonry-facades\/117701\/"]}]},{"@type":"BreadcrumbList","@id":"https:\/\/www.pbctoday.co.uk\/news\/building-control-news\/fire-performance-requirements-cavity-trays-masonry-facades\/117701\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.pbctoday.co.uk\/news\/"},{"@type":"ListItem","position":2,"name":"Understanding the changing fire performance requirements of cavity trays in masonry facades"}]},{"@type":"WebSite","@id":"https:\/\/www.pbctoday.co.uk\/news\/#website","url":"https:\/\/www.pbctoday.co.uk\/news\/","name":"Planning, Building &amp; Construction Today","description":"The Latest Planning, Building &amp; Construction News","publisher":{"@id":"https:\/\/www.pbctoday.co.uk\/news\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.pbctoday.co.uk\/news\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/www.pbctoday.co.uk\/news\/#organization","name":"Planning, Building & Construction Today","alternateName":"PBC Today","url":"https:\/\/www.pbctoday.co.uk\/news\/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.pbctoday.co.uk\/news\/#\/schema\/logo\/image\/","url":"https:\/\/www.pbctoday.co.uk\/news\/wp-content\/uploads\/2022\/01\/pbctoday-logo-yoast-seo-organisation-1920-1080-001.jpg","contentUrl":"https:\/\/www.pbctoday.co.uk\/news\/wp-content\/uploads\/2022\/01\/pbctoday-logo-yoast-seo-organisation-1920-1080-001.jpg","width":1920,"height":1080,"caption":"Planning, Building & Construction Today"},"image":{"@id":"https:\/\/www.pbctoday.co.uk\/news\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.facebook.com\/PBCToday\/","https:\/\/x.com\/PBC_Today"]},{"@type":"Person","@id":"https:\/\/www.pbctoday.co.uk\/news\/#\/schema\/person\/dd16f5e0e89ad310c0ff814f9325eb65","name":"Steph Carpenter","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.pbctoday.co.uk\/news\/#\/schema\/person\/image\/","url":"https:\/\/secure.gravatar.com\/avatar\/97a073c56b415b32c4d1d8ee9ef9a0ce42224c6532ccc712f228b71f15b4e650?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/97a073c56b415b32c4d1d8ee9ef9a0ce42224c6532ccc712f228b71f15b4e650?s=96&d=mm&r=g","caption":"Steph Carpenter"},"sameAs":["http:\/\/www.pbctoday.co.uk"],"url":"https:\/\/www.pbctoday.co.uk\/news\/author\/stephhazlegreaves\/"}]}},"publishpress_future_action":{"enabled":false,"date":"2026-09-30 12:13:58","action":"change-status","newStatus":"draft","terms":[],"taxonomy":"category","extraData":[]},"publishpress_future_workflow_manual_trigger":{"enabledWorkflows":[]},"_links":{"self":[{"href":"https:\/\/www.pbctoday.co.uk\/news\/wp-json\/wp\/v2\/posts\/117701","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.pbctoday.co.uk\/news\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.pbctoday.co.uk\/news\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.pbctoday.co.uk\/news\/wp-json\/wp\/v2\/users\/17"}],"replies":[{"embeddable":true,"href":"https:\/\/www.pbctoday.co.uk\/news\/wp-json\/wp\/v2\/comments?post=117701"}],"version-history":[{"count":0,"href":"https:\/\/www.pbctoday.co.uk\/news\/wp-json\/wp\/v2\/posts\/117701\/revisions"}],"wp:attachment":[{"href":"https:\/\/www.pbctoday.co.uk\/news\/wp-json\/wp\/v2\/media?parent=117701"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.pbctoday.co.uk\/news\/wp-json\/wp\/v2\/categories?post=117701"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.pbctoday.co.uk\/news\/wp-json\/wp\/v2\/tags?post=117701"},{"taxonomy":"stakeholder_rel_tag","embeddable":true,"href":"https:\/\/www.pbctoday.co.uk\/news\/wp-json\/wp\/v2\/stakeholder_rel_tag?post=117701"},{"taxonomy":"contributor_rel_tag","embeddable":true,"href":"https:\/\/www.pbctoday.co.uk\/news\/wp-json\/wp\/v2\/contributor_rel_tag?post=117701"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}