{"id":39357,"date":"2018-03-12T14:36:30","date_gmt":"2018-03-12T14:36:30","guid":{"rendered":"https:\/\/www.pbctoday.co.uk\/news\/?p=39357"},"modified":"2018-04-29T18:14:32","modified_gmt":"2018-04-29T17:14:32","slug":"new-fia-research-sheds-light-on-detection-of-stratified-smoke","status":"publish","type":"post","link":"https:\/\/www.pbctoday.co.uk\/news\/health-safety-news\/new-fia-research-sheds-light-on-detection-of-stratified-smoke\/39357\/","title":{"rendered":"New Fire Industry Association research sheds light on detection of stratified smoke"},"content":{"rendered":"<h2>Robert Yates, Technical Manager of the Fire Industry Association, and Peter Massingberd-Mundy, Technology and Practices Manager at FIA member Xtralis, discuss the FIA\u2019s recent research into the challenge of detecting stratified smoke<\/h2>\n<p><a href=\"https:\/\/www.pbctoday.co.uk\/news\/health-safety-news\/change-fire-detection-alarm-industry\/37520\/\">Fire detection<\/a> in large open spaces has often proved to be challenging. BS5839-1 provides clear guidelines for detection at the ceiling and this may be perfectly sufficient for many applications. However, a few designers have been embarrassed to receive customer complaints of detection failing to respond to a fire despite the system being compliant with the code of practice.<\/p>\n<p>The cause of such poor performance can be attributed to stratification. This is where the fire has insufficient energy for the resultant smoke plume to rise to the ceiling because it has cooled to the temperature of the surrounding air and lost buoyancy, spreading out in a layer below where the detection is sited.<\/p>\n<p>The challenge for system designers is to predict when and where stratification may occur. In practice, it is almost impossible to reliably predict the height at which the smoke layer will form because it depends upon the size and energy of fire \u2013 and the temperature gradient in the protected space. This gradient can in itself be influenced by many factors, such as differing weather conditions, time of day, building occupation, heating control etc. As a consequence, it is often simply argued that as the fire develops, the heat output increases, hotter smoke will break through any thermal barrier and ceiling-mounted detectors will eventually operate.<\/p>\n<p>In spaces where smoke stratification is considered to be a risk, BS5839-1 (and other similar codes) has, for many years, recommended that a layer of several beam detectors is installed \u2013 spaced sufficiently close to each other so the rising smoke plume is unlikely to pass through the layer undetected. In reality, this recommendation is rarely followed because the number of beam detectors needed is prohibitively expensive.<\/p>\n<p>Instead, many designers instinctively apply the use of angled beam detectors in the expectation that they will be obscured by the smoke layer no matter the height at which it forms.<\/p>\n<p>This alternative approach (using angled beams) was first included in BS5839-1 in 2013 but no specific guidance was provided as to where to place them because such an approach has never been fully researched.<\/p>\n<p>Thus, the <a href=\"https:\/\/www.pbctoday.co.uk\/news\/stakeholders\/fia-fire-industry-association\/35063\/\">Fire Industry Association<\/a> accepted a proposal from some of its members to invest in a research project to investigate the effectiveness of angled beams and provide data to support guidance as to where they should best be positioned.<\/p>\n<h3>The research<\/h3>\n<p>Using software called Fire Dynamic Simulator (FDS), the Fire Industry Association, in partnership with researchers of fire science at the <a href=\"https:\/\/www.ed.ac.uk\/\">University of Edinburgh<\/a>, modelled a series of fire scenarios in a 25m high space to simulate the effect of key variables such as fire size and temperature gradient on the characteristics of the smoke layer.<\/p>\n<p>For those unfamiliar with FDS, it uses complex computerised mathematical modelling systems to simulate and predict the way that smoke travels and how it rises within a building. Moreover, it includes models that can be used to predict the activation of smoke detectors (including beam and aspirating smoke detectors). These models were fundamentally improved as part of the project to accurately model angled beams \u2013 of which there were over 100 included in the simulations.<\/p>\n<h3>The findings<\/h3>\n<p>As with all such analysis, the absolute accuracy of the results cannot be relied on until it has been verified. Despite this caveat, the results provided useful insights into the relative performance of detectors in different positions and the visualisation afforded by\u00a0 SmokeView shed light on how the smoke layer develops.<\/p>\n<p>The first finding was that the tight spacing (\u00bc height) recommended in BS5839-1 (for interstitial beams intended to detect the rising column of smoke) should not be relaxed. For example, if the interstitial beams are installed at 12m they need to be spaced every 3m \u2013 requiring ~ 5 times more devices compared to the 15m spacing recommended for the ceiling mounted beam detectors.<\/p>\n<p>The second finding was that the predicted response of angled beam detectors passing through a stratified layer of smoke (resulting from a small fire when there is a temperature gradient) is similar to the response of beam detectors positioned on a ceiling (to the same small fire when there is no temperature gradient to cause the smoke to stratify). This was an important finding as it confirms that angled devices are likely to be effective.<\/p>\n<p>One observation, which differs from common\/intuitive thinking, is that the horizontal velocity in the smoke layer reduces as the layer spreads. The research indicates that the layer does not continue to stretch outwards across the room indefinitely, but instead it tends to deepen around the centre and to become more dense. It is therefore important when looking a design with angled beams that consideration is given to the extent (and speed) of the spread of the smoke layer.<\/p>\n<h3>Applying the research<\/h3>\n<p>The findings thus far are reflected in the current advice in BS5839-1 for installing angled beam detector \u2013 particularly in the note under clause 22.5d). One additional recommendation from the research which has not been reflected into BS5839-1 yet is that when installing angled beams, they are best deployed in a criss-cross arrangement (see diagram). This is intended to ensure that the distance to a beam at any height is not excessive.<\/p>\n<h3>The future<\/h3>\n<p>From this short overview of the research underpinning the current recommendations for angled beams, it is clear that further analysis and validation is needed. In anticipation of this, the FIA has agreed to sponsor a second phase of research into the challenges of detecting stratified smoke.<\/p>\n<p>The Fire Industry Association, the UK\u2019s largest trade association in the fire protection sector, not only contributes to writing best practice guides and<\/p>\n<p>revising British Standards, but also is a powerful investor in scientific research into the behaviour of fire and a wide range of other issues including smoke detection and the capabilities of fire detection and alarm technology.<\/p>\n<p>This project was sponsored by the FIA in conjunction with Laluvein Consulting Ltd, Fire Fighting Enterprises Limited and Xtralis (UK) Ltd (part of Honeywell). The FDS modelling was undertaken by Ben Ralph from University of Edinburgh, Fire Safety Engineering. To learn more about optical beam detection, visit the FIA\u2019s Resources section on the website, where a vast technical digital library can be accessed.<\/p>\n<p><strong>Robert Yates<\/strong><br \/>\nTechnical Manager<br \/>\nFire Industry Association<br \/>\n<a href=\"mailto:info@fia.uk.com\">info@fia.uk.com<\/a><br \/>\n<a href=\"http:\/\/www.fia.com\">www.fia.com<\/a><br \/>\nTwitter: <a href=\"http:\/\/www.twitter.com\/FireIndustry\">@FireIndustry<\/a><\/p>\n<div class=\"mk-custom-module-container\">\n<\/div>","protected":false},"excerpt":{"rendered":"<p>Robert Yates, Technical Manager of the Fire Industry Association, and Peter Massingberd-Mundy, Technology and Practices Manager at FIA member Xtralis, discuss the FIA\u2019s recent research into the challenge of detecting stratified smoke<\/p>\n","protected":false},"author":16,"featured_media":0,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"_monsterinsights_skip_tracking":false,"_monsterinsights_sitenote_active":false,"_monsterinsights_sitenote_note":"","_monsterinsights_sitenote_category":0,"footnotes":""},"categories":[309],"tags":[110,820,787],"stakeholder_rel_tag":[172440],"contributor_rel_tag":[],"class_list":{"0":"post-39357","1":"post","2":"type-post","3":"status-publish","4":"format-standard","6":"category-health-safety-news","7":"tag-fire-safety-management","8":"tag-pbc-today-april-2018","9":"tag-sh-fia","10":"stakeholder_rel_tag-fia"},"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO Premium plugin v26.9 (Yoast SEO v26.9) - https:\/\/yoast.com\/product\/yoast-seo-premium-wordpress\/ -->\n<title>New Fire Industry Association research sheds light on detection of stratified smoke | Planning, Building &amp; Construction Today<\/title>\n<meta name=\"description\" content=\"Robert Yates, Technical Manager of the Fire Industry Association, and Peter Massingberd-Mundy, Technology and Practices Manager at FIA member Xtralis, discuss the FIA\u2019s recent research into the challenge of detecting stratified smoke\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.pbctoday.co.uk\/news\/health-safety-news\/new-fia-research-sheds-light-on-detection-of-stratified-smoke\/39357\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"New Fire Industry Association research sheds light on detection of stratified smoke\" \/>\n<meta property=\"og:description\" content=\"Robert Yates, Technical Manager of the Fire Industry Association, and Peter Massingberd-Mundy, Technology and Practices Manager at FIA member Xtralis, discuss the FIA\u2019s recent research into the challenge of detecting stratified smoke\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.pbctoday.co.uk\/news\/health-safety-news\/new-fia-research-sheds-light-on-detection-of-stratified-smoke\/39357\/\" \/>\n<meta property=\"og:site_name\" content=\"Planning, Building &amp; Construction Today\" \/>\n<meta property=\"article:publisher\" content=\"https:\/\/www.facebook.com\/PBCToday\/\" \/>\n<meta property=\"article:published_time\" content=\"2018-03-12T14:36:30+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2018-04-29T17:14:32+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.pbctoday.co.uk\/news\/wp-content\/uploads\/2018\/03\/R-Yates.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"800\" \/>\n\t<meta property=\"og:image:height\" content=\"532\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"Steph Blundell\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:creator\" content=\"@https:\/\/twitter.com\/Steph_PBCToday\" \/>\n<meta name=\"twitter:site\" content=\"@PBC_Today\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\/\/www.pbctoday.co.uk\/news\/health-safety-news\/new-fia-research-sheds-light-on-detection-of-stratified-smoke\/39357\/#article\",\"isPartOf\":{\"@id\":\"https:\/\/www.pbctoday.co.uk\/news\/health-safety-news\/new-fia-research-sheds-light-on-detection-of-stratified-smoke\/39357\/\"},\"author\":{\"name\":\"Steph Blundell\",\"@id\":\"https:\/\/www.pbctoday.co.uk\/news\/#\/schema\/person\/baf6766a43e70a35cada0c600519a2fb\"},\"headline\":\"New Fire Industry Association research sheds light on detection of stratified smoke\",\"datePublished\":\"2018-03-12T14:36:30+00:00\",\"dateModified\":\"2018-04-29T17:14:32+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\/\/www.pbctoday.co.uk\/news\/health-safety-news\/new-fia-research-sheds-light-on-detection-of-stratified-smoke\/39357\/\"},\"wordCount\":1097,\"commentCount\":0,\"publisher\":{\"@id\":\"https:\/\/www.pbctoday.co.uk\/news\/#organization\"},\"keywords\":[\"Fire Safety Management\",\"PBC Today April 2018\",\"SH FIA\"],\"articleSection\":[\"Health &amp; Safety News\"],\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\/\/www.pbctoday.co.uk\/news\/health-safety-news\/new-fia-research-sheds-light-on-detection-of-stratified-smoke\/39357\/#respond\"]}],\"copyrightYear\":\"2018\",\"copyrightHolder\":{\"@id\":\"https:\/\/www.pbctoday.co.uk\/news\/#organization\"}},{\"@type\":\"WebPage\",\"@id\":\"https:\/\/www.pbctoday.co.uk\/news\/health-safety-news\/new-fia-research-sheds-light-on-detection-of-stratified-smoke\/39357\/\",\"url\":\"https:\/\/www.pbctoday.co.uk\/news\/health-safety-news\/new-fia-research-sheds-light-on-detection-of-stratified-smoke\/39357\/\",\"name\":\"New Fire Industry Association research sheds light on detection of stratified smoke | Planning, Building &amp; Construction Today\",\"isPartOf\":{\"@id\":\"https:\/\/www.pbctoday.co.uk\/news\/#website\"},\"datePublished\":\"2018-03-12T14:36:30+00:00\",\"dateModified\":\"2018-04-29T17:14:32+00:00\",\"description\":\"Robert Yates, Technical Manager of the Fire Industry Association, and Peter Massingberd-Mundy, Technology and Practices Manager at FIA member Xtralis, discuss the FIA\u2019s recent research into the challenge of detecting stratified smoke\",\"breadcrumb\":{\"@id\":\"https:\/\/www.pbctoday.co.uk\/news\/health-safety-news\/new-fia-research-sheds-light-on-detection-of-stratified-smoke\/39357\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/www.pbctoday.co.uk\/news\/health-safety-news\/new-fia-research-sheds-light-on-detection-of-stratified-smoke\/39357\/\"]}]},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/www.pbctoday.co.uk\/news\/health-safety-news\/new-fia-research-sheds-light-on-detection-of-stratified-smoke\/39357\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/www.pbctoday.co.uk\/news\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"New Fire Industry Association research sheds light on detection of stratified smoke\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/www.pbctoday.co.uk\/news\/#website\",\"url\":\"https:\/\/www.pbctoday.co.uk\/news\/\",\"name\":\"Planning, Building &amp; Construction Today\",\"description\":\"The Latest Planning, Building &amp; Construction News\",\"publisher\":{\"@id\":\"https:\/\/www.pbctoday.co.uk\/news\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/www.pbctoday.co.uk\/news\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https:\/\/www.pbctoday.co.uk\/news\/#organization\",\"name\":\"Planning, Building & Construction Today\",\"alternateName\":\"PBC Today\",\"url\":\"https:\/\/www.pbctoday.co.uk\/news\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/www.pbctoday.co.uk\/news\/#\/schema\/logo\/image\/\",\"url\":\"https:\/\/www.pbctoday.co.uk\/news\/wp-content\/uploads\/2022\/01\/pbctoday-logo-yoast-seo-organisation-1920-1080-001.jpg\",\"contentUrl\":\"https:\/\/www.pbctoday.co.uk\/news\/wp-content\/uploads\/2022\/01\/pbctoday-logo-yoast-seo-organisation-1920-1080-001.jpg\",\"width\":1920,\"height\":1080,\"caption\":\"Planning, Building & Construction Today\"},\"image\":{\"@id\":\"https:\/\/www.pbctoday.co.uk\/news\/#\/schema\/logo\/image\/\"},\"sameAs\":[\"https:\/\/www.facebook.com\/PBCToday\/\",\"https:\/\/x.com\/PBC_Today\"]},{\"@type\":\"Person\",\"@id\":\"https:\/\/www.pbctoday.co.uk\/news\/#\/schema\/person\/baf6766a43e70a35cada0c600519a2fb\",\"name\":\"Steph Blundell\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/www.pbctoday.co.uk\/news\/#\/schema\/person\/image\/\",\"url\":\"https:\/\/secure.gravatar.com\/avatar\/62283f53e7b9ae55cd3516832342b97ce87c86f2c2130dfce68124d194b36df8?s=96&d=mm&r=g\",\"contentUrl\":\"https:\/\/secure.gravatar.com\/avatar\/62283f53e7b9ae55cd3516832342b97ce87c86f2c2130dfce68124d194b36df8?s=96&d=mm&r=g\",\"caption\":\"Steph Blundell\"},\"description\":\"Steph is the Senior Digital Editor here at PBC. When she\u2019s not working hard on cranking out first-class content for our online viewers to enjoy, she\u2019s keeping our social media lively and up to date\u2026 you could call her a social media guru? We\u2019re sure she\u2019d like that. With a BA in English and Journalism, Steph isn\u2019t fazed by attention to detail; on the contrary, she enjoys getting her teeth into a good article. In her downtime Steph loves nothing more than getting together with friends to enjoy a few (several) gin and tonics. Think you\u2019ve got some content Steph would be interested in? You can contact her either by phone on (01270) 502876 or by email at sblundell@pbctoday.co.uk\",\"sameAs\":[\"https:\/\/www.pbctoday.co.uk\",\"https:\/\/www.linkedin.com\/in\/steph-blundell\/\",\"https:\/\/x.com\/https:\/\/twitter.com\/Steph_PBCToday\"],\"url\":\"https:\/\/www.pbctoday.co.uk\/news\/author\/stephblundell\/\"}]}<\/script>\n<!-- \/ Yoast SEO Premium plugin. -->","yoast_head_json":{"title":"New Fire Industry Association research sheds light on detection of stratified smoke | Planning, Building &amp; Construction Today","description":"Robert Yates, Technical Manager of the Fire Industry Association, and Peter Massingberd-Mundy, Technology and Practices Manager at FIA member Xtralis, discuss the FIA\u2019s recent research into the challenge of detecting stratified smoke","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.pbctoday.co.uk\/news\/health-safety-news\/new-fia-research-sheds-light-on-detection-of-stratified-smoke\/39357\/","og_locale":"en_US","og_type":"article","og_title":"New Fire Industry Association research sheds light on detection of stratified smoke","og_description":"Robert Yates, Technical Manager of the Fire Industry Association, and Peter Massingberd-Mundy, Technology and Practices Manager at FIA member Xtralis, discuss the FIA\u2019s recent research into the challenge of detecting stratified smoke","og_url":"https:\/\/www.pbctoday.co.uk\/news\/health-safety-news\/new-fia-research-sheds-light-on-detection-of-stratified-smoke\/39357\/","og_site_name":"Planning, Building &amp; Construction Today","article_publisher":"https:\/\/www.facebook.com\/PBCToday\/","article_published_time":"2018-03-12T14:36:30+00:00","article_modified_time":"2018-04-29T17:14:32+00:00","og_image":[{"width":800,"height":532,"url":"https:\/\/www.pbctoday.co.uk\/news\/wp-content\/uploads\/2018\/03\/R-Yates.jpg","type":"image\/jpeg"}],"author":"Steph Blundell","twitter_card":"summary_large_image","twitter_creator":"@https:\/\/twitter.com\/Steph_PBCToday","twitter_site":"@PBC_Today","schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.pbctoday.co.uk\/news\/health-safety-news\/new-fia-research-sheds-light-on-detection-of-stratified-smoke\/39357\/#article","isPartOf":{"@id":"https:\/\/www.pbctoday.co.uk\/news\/health-safety-news\/new-fia-research-sheds-light-on-detection-of-stratified-smoke\/39357\/"},"author":{"name":"Steph Blundell","@id":"https:\/\/www.pbctoday.co.uk\/news\/#\/schema\/person\/baf6766a43e70a35cada0c600519a2fb"},"headline":"New Fire Industry Association research sheds light on detection of stratified smoke","datePublished":"2018-03-12T14:36:30+00:00","dateModified":"2018-04-29T17:14:32+00:00","mainEntityOfPage":{"@id":"https:\/\/www.pbctoday.co.uk\/news\/health-safety-news\/new-fia-research-sheds-light-on-detection-of-stratified-smoke\/39357\/"},"wordCount":1097,"commentCount":0,"publisher":{"@id":"https:\/\/www.pbctoday.co.uk\/news\/#organization"},"keywords":["Fire Safety Management","PBC Today April 2018","SH FIA"],"articleSection":["Health &amp; Safety News"],"inLanguage":"en-US","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/www.pbctoday.co.uk\/news\/health-safety-news\/new-fia-research-sheds-light-on-detection-of-stratified-smoke\/39357\/#respond"]}],"copyrightYear":"2018","copyrightHolder":{"@id":"https:\/\/www.pbctoday.co.uk\/news\/#organization"}},{"@type":"WebPage","@id":"https:\/\/www.pbctoday.co.uk\/news\/health-safety-news\/new-fia-research-sheds-light-on-detection-of-stratified-smoke\/39357\/","url":"https:\/\/www.pbctoday.co.uk\/news\/health-safety-news\/new-fia-research-sheds-light-on-detection-of-stratified-smoke\/39357\/","name":"New Fire Industry Association research sheds light on detection of stratified smoke | Planning, Building &amp; Construction Today","isPartOf":{"@id":"https:\/\/www.pbctoday.co.uk\/news\/#website"},"datePublished":"2018-03-12T14:36:30+00:00","dateModified":"2018-04-29T17:14:32+00:00","description":"Robert Yates, Technical Manager of the Fire Industry Association, and Peter Massingberd-Mundy, Technology and Practices Manager at FIA member Xtralis, discuss the FIA\u2019s recent research into the challenge of detecting stratified smoke","breadcrumb":{"@id":"https:\/\/www.pbctoday.co.uk\/news\/health-safety-news\/new-fia-research-sheds-light-on-detection-of-stratified-smoke\/39357\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.pbctoday.co.uk\/news\/health-safety-news\/new-fia-research-sheds-light-on-detection-of-stratified-smoke\/39357\/"]}]},{"@type":"BreadcrumbList","@id":"https:\/\/www.pbctoday.co.uk\/news\/health-safety-news\/new-fia-research-sheds-light-on-detection-of-stratified-smoke\/39357\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.pbctoday.co.uk\/news\/"},{"@type":"ListItem","position":2,"name":"New Fire Industry Association research sheds light on detection of stratified smoke"}]},{"@type":"WebSite","@id":"https:\/\/www.pbctoday.co.uk\/news\/#website","url":"https:\/\/www.pbctoday.co.uk\/news\/","name":"Planning, Building &amp; Construction Today","description":"The Latest Planning, Building &amp; Construction News","publisher":{"@id":"https:\/\/www.pbctoday.co.uk\/news\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.pbctoday.co.uk\/news\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/www.pbctoday.co.uk\/news\/#organization","name":"Planning, Building & Construction Today","alternateName":"PBC Today","url":"https:\/\/www.pbctoday.co.uk\/news\/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.pbctoday.co.uk\/news\/#\/schema\/logo\/image\/","url":"https:\/\/www.pbctoday.co.uk\/news\/wp-content\/uploads\/2022\/01\/pbctoday-logo-yoast-seo-organisation-1920-1080-001.jpg","contentUrl":"https:\/\/www.pbctoday.co.uk\/news\/wp-content\/uploads\/2022\/01\/pbctoday-logo-yoast-seo-organisation-1920-1080-001.jpg","width":1920,"height":1080,"caption":"Planning, Building & Construction Today"},"image":{"@id":"https:\/\/www.pbctoday.co.uk\/news\/#\/schema\/logo\/image\/"},"sameAs":["https:\/\/www.facebook.com\/PBCToday\/","https:\/\/x.com\/PBC_Today"]},{"@type":"Person","@id":"https:\/\/www.pbctoday.co.uk\/news\/#\/schema\/person\/baf6766a43e70a35cada0c600519a2fb","name":"Steph Blundell","image":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.pbctoday.co.uk\/news\/#\/schema\/person\/image\/","url":"https:\/\/secure.gravatar.com\/avatar\/62283f53e7b9ae55cd3516832342b97ce87c86f2c2130dfce68124d194b36df8?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/62283f53e7b9ae55cd3516832342b97ce87c86f2c2130dfce68124d194b36df8?s=96&d=mm&r=g","caption":"Steph Blundell"},"description":"Steph is the Senior Digital Editor here at PBC. When she\u2019s not working hard on cranking out first-class content for our online viewers to enjoy, she\u2019s keeping our social media lively and up to date\u2026 you could call her a social media guru? We\u2019re sure she\u2019d like that. With a BA in English and Journalism, Steph isn\u2019t fazed by attention to detail; on the contrary, she enjoys getting her teeth into a good article. In her downtime Steph loves nothing more than getting together with friends to enjoy a few (several) gin and tonics. Think you\u2019ve got some content Steph would be interested in? You can contact her either by phone on (01270) 502876 or by email at sblundell@pbctoday.co.uk","sameAs":["https:\/\/www.pbctoday.co.uk","https:\/\/www.linkedin.com\/in\/steph-blundell\/","https:\/\/x.com\/https:\/\/twitter.com\/Steph_PBCToday"],"url":"https:\/\/www.pbctoday.co.uk\/news\/author\/stephblundell\/"}]}},"publishpress_future_action":{"enabled":false,"date":"2026-10-14 02:22:12","action":"change-status","newStatus":"draft","terms":[],"taxonomy":"category","extraData":[]},"publishpress_future_workflow_manual_trigger":{"enabledWorkflows":[]},"_links":{"self":[{"href":"https:\/\/www.pbctoday.co.uk\/news\/wp-json\/wp\/v2\/posts\/39357","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.pbctoday.co.uk\/news\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.pbctoday.co.uk\/news\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.pbctoday.co.uk\/news\/wp-json\/wp\/v2\/users\/16"}],"replies":[{"embeddable":true,"href":"https:\/\/www.pbctoday.co.uk\/news\/wp-json\/wp\/v2\/comments?post=39357"}],"version-history":[{"count":0,"href":"https:\/\/www.pbctoday.co.uk\/news\/wp-json\/wp\/v2\/posts\/39357\/revisions"}],"wp:attachment":[{"href":"https:\/\/www.pbctoday.co.uk\/news\/wp-json\/wp\/v2\/media?parent=39357"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.pbctoday.co.uk\/news\/wp-json\/wp\/v2\/categories?post=39357"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.pbctoday.co.uk\/news\/wp-json\/wp\/v2\/tags?post=39357"},{"taxonomy":"stakeholder_rel_tag","embeddable":true,"href":"https:\/\/www.pbctoday.co.uk\/news\/wp-json\/wp\/v2\/stakeholder_rel_tag?post=39357"},{"taxonomy":"contributor_rel_tag","embeddable":true,"href":"https:\/\/www.pbctoday.co.uk\/news\/wp-json\/wp\/v2\/contributor_rel_tag?post=39357"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}